Warm roof eaves ventilation.
For a simple duo pitch roof bs 5250 specifies sufficient ventilation as being.
Eaves ventilation is a simple and effective way of providing the necessary air movement within a cold roof.
A vapour membrane should be added to the underside of the insulation and tacked to the joists before applying the plasterboard.
Intake vents located at the lowest part of the roof under the eaves allow cool air to enter the attic.
Klober circular soffit vents provide eaves ventilation through the soffit and are a particularly easy option to install.
Quantity discount inc vat 1 49.
Eaves soffits and fascias.
Ventilation must also be provided through the eaves or roof ridges using fascia vents or the skylight upstand on the roof.
Klober flat roof vents.
Home roof ventilation eaves ventilation warm roof rafter tray x 400mm harcon rt41.
Warm deck the insulation is placed over the rafters and then a felt is placed on top.
Roof voids must be ventilated in order to stop warm air condensing on cold surfaces.
The air gap dimensions shown on the drawings are the minimum widths required for clear continuous ventilation air paths at the eaves.
Ventilation at the eaves.
Sometimes we get asked why choose a cold roof or warm roof.
25mm at eaves on each slope and 5mm at ridge.
Hot air exhaust vents located at the peak of the roof allow hot air to escape.
These are some of the reasons why a cold roof can be cheaper as ridged warm roof insulation tends to be more expensive a warm roof is sometimes the only option when it is difficult to get the required cross ventilation.
To provide ventilation opening points can usually be provided on the following areas of a pitched roof.
Ventilation is also required at eaves level to a degree which equates to a 25mm continuous strip see figure 7.
This is to be provided by an unobstructed 50mm air gap between the roof deck and insulation.
Slating and tiling for pitched roofs and vertical cladding code of practice recommends that roof ventilation be provided in accordance with bs 5250.
Cold deck flat roof construction is more prone to defects and it has a shorter lifespan.
Condensation encourages rot and mould growth.
Warm roof rafter tray x 400mm harcon rt41.
The battening and tiling is then fixed down over.
Ventilation openings either at the eaves or upstand.
If ridge or eaves ventilation is not possible ventilation tiles can be used at high or low level to achieve the required airflow.
Rt41 0 82 inc vat 0 98 corovent 400mm single rafter tray provides 25mm air gap per lm for warm roofs or pitches below 15 degrees rt41.